Journal Article IMPULSE-2024-00011

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Spatial Model of the Organization of Chromatin in the Nucleus of a Biological Cell According to Small-Angle Scattering Data

 ;  ;  ;  ;  ;  ;  ;  ;

2023
Springer Heidelberg [u.a.]

JETP letters 118(10), 779 - 784 () [10.1134/S0021364023601501]

Please use a persistent id in citations: doi:

Abstract: Small-angle neutron and X-ray scattering data for HeLa nuclei with the normal and suppressed transcription activities are reported. Small-angle neutron scattering data demonstrate the presence of a bifractal structure inside a nucleus. The logarithmic fractal structure is observed in the range from the size of the nucleus to several hundreds of nanometer, whereas the volume fractal structure exists at smaller scales down to a nucleosome structure. Small-angle X-ray scattering data show that the presence of the volume fractal structure correlates with the transcription activity of a cell. In view of the successful description of chromatin by the fractal globule model (Hi–C method data), a scenario for the formation of the bifractal structure inside the nucleus has been proposed. A system of transport channels (logarithmic fractal) is located inside close-packed chromatin, whereas active chromatin is localized near transport channels or inside them and forms volume fractal structures due to the transcription activity. Thus, the logarithmic fractal structure ensures the uniform distribution of voids at various scales, which is potentially necessary for the transcription and transport of substances inside the nucleus, whereas the volume fractal structure is due to the transcription activity of the cell.

Keyword(s): Health and Life (1st) ; Soft Condensed Matter (2nd) ; Medicine (2nd) ; Biology (2nd)

Classification:

Contributing Institute(s):
  1. KWS2 (KWS2)
  2. KWS3 (KWS3)
  3. MLZ (MLZ)
  4. Users (Users)
Experiment(s):
  1. KWS-2: Small angle scattering diffractometer (NL3ao)
  2. KWS-3: Very small angle scattering diffractometer with focusing mirror (NL3auS)

Click to display QR Code for this record

The record appears in these collections:
Dokumenttypen > Aufsätze > Zeitschriftenaufsätze
Workflow collections > Öffentliche Einträge
Workflow collections > Publikationsdatenbank
Institutssammlungen > KWS3
Institutssammlungen > KWS2
Institutssammlungen > MLZ
Publications database

 Datensatz erzeugt am 2024-01-16, letzte Änderung am 2024-01-24


Volltext:
Volltext herunterladen PDF Volltext herunterladen PDF (PDFA)
Externer link:
Volltext herunterladenVolltext
Dieses Dokument bewerten:

Rate this document:
1
2
3
 
(Bisher nicht rezensiert)