Abstract: We present a novel design for a macrostructured cathode that can be coated with a thin layer of the 10B solid converter and mounted to replace the Boron-lined flat parallel plates of a proportional counter used for slow neutron detection. The proposed design consists of a 3D regular pattern exhibiting millimeter deep grooves with an opening angle of α = 45 ° , which could be created in the substrate material by milling or forming. When a commonly used coating method like magnetron sputtering is employed to deposit the Boron-layer, due to the line-of-sight distribution of the ions, the thickness of the coating on the side of the grooves will be reduced by a factor ∼ sin α / 2 with respect to the thickness of the layer deposited on a flat surface normal to the ion flux. The effective neutron absorption film thickness is in this case similar for the sidewalls of the grooves and a surface at normal incidence, yielding comparable absorption efficiencies. However, the escape efficiency for the reaction products is higher for the sidewalls, owing to the thinner coating. This leads to a higher overall detection efficiency for the grooved cathode when compared to a flat cathode with the same surface area and coated with a Boron layer with roughly the same thickness. In this paper we present and discuss the GEANT4 simulations performed to optimize the geometry of the cathode, the manufacturing and coating by magnetron sputtering, as well as the proof-of-principle measurements carried out in order to assess the performance of the proposed design.

Keyword(s): Instrument and Method Development (1st) ; Others (1st) ; Instrument and Method Development (2nd) ; Physics and Chemistry General

Classification:

Note: Record converted 2014-10-14 05:10:07

Contributing Institute(s):
  1. DEL
Experiment(s):
  1. Detectors/Electronics

Click to display QR Code for this record

The record appears in these collections:
Dokumenttypen > Aufsätze > Zeitschriftenaufsätze
Workflow collections > Öffentliche Einträge
Workflow collections > Publikationsdatenbank
Workflow collections > In Bearbeitung
Institutssammlungen > DEL
Publications database

 Datensatz erzeugt am 2014-10-17, letzte Änderung am 2017-03-02


Externer link:
Volltext herunterladen
Volltext
Dieses Dokument bewerten:

Rate this document:
1
2
3
 
(Bisher nicht rezensiert)